Digital anatomical study of the superior pubic ramus screw channel
YANG Yong, WANG Lei, WANG Fu-Chuan, ZHANG Shao-Wu, DONG Yun
Chinese Journal of Clinical Anatomy ›› 2013, Vol. 31 ›› Issue (4) : 397-401.
Digital anatomical study of the superior pubic ramus screw channel
Objective To investigate the safe range of intramedullary screw channel of superior pubic ramus fractures with the methods of digital anatomy. Methods A retrospective analysis was conducted with computed tomography (CT) images of pelvis from17 adult patients (34 cases of hemipelvis). We built virtual cylinder of intramedullary screw channel with Mimics according to the common types of superior pubic ramus fracture. With three-dimensional measurement tools, we measured the maximum width, depth, range of entry points and angles of the screw channels, determined the patterns of them and the scope of the security. Results For medial 1/2 fractures, the virtual cylindrical was of an average of (9.64±0.79) mm in maximum diameter, (67.88±6.07) mm in length and sagittal screw angle ranged from (44.03±2.29)° to (50.41±3.33)°; in terms of the lateral 1/2 fracture, the maximum diameter of the virtual cylindrical was (11.25±1.45) mm, (96.82±6.76) mm in length, the angle between the screw and the sagittal plane ranged from (36.12±2.76)° to (43.38± 3.30)°. The differences between men and women were statistically significant, the data of different location of fractures between the two groups were statistically significant. Conclusion Digital anatomical studies of the safe range of intramedullary screw channel of superior pubic ramus fractures increase the safety and accuracy of the intramedullary screws fixation.
Superior pubic ramus / Screw channel / Three-dimensional reconstruction / Digital anatomy / Internal fixation
[1] Giannoudis PV, Grotz MR, Tzioupis C, et al. Prevalence of pelvic fractures, associated injuries, and mortality: the United Kingdom perspective
[J]. J Trauma, 2007, 63(4): 875-883.
[2] Simonian PT, Routt ML Jr, Harrington RM, et al. Internal fixation of the unstable anterior pelvic ring: a biomechanical comparison of standard plating techniques and the retrograde medullary superior pubic ramus screw
[J]. J Orthop Trauma, 1994, 8(6): 476-482.
[3] Rommens PM, Hessmann MH. Staged reconstruction of pelvic ring disruption: differences in morbidity, mortality, radiologic results, and functional outcomes between B1, B2/B3, and C-type lesions
[J]. J Orthop Trauma, 2002, 16(2): 92-98.
[4]王庆贤, 张英泽, 潘进社, 等. 耻骨上支逆行拉力螺钉内固定的应用解剖学研究
[J]. 中国临床解剖学杂志, 2005, 24(6): 617-619, 622.
[5]裘邯军, 李明, 徐荣明, 等. 耻骨上支髓内螺钉固定的应用解剖学研究
[J]. 现代实用医学, 2010, 22(2): 144-147.
[6]郑琦, 廖胜辉, 石仕元, 等. 髋臼前柱螺钉内固定的最优化计算机辅助测量
[J]. 解剖学杂志,2007,30(5): 602-605.
/
〈 |
|
〉 |