Measurement of orbital volume in zygomaticomaxillary complex fractures and its clinical significance
YIN Xue-Min, REN Xiao-Xu, LIU Chi, LI Yan
Chinese Journal of Clinical Anatomy ›› 2011, Vol. 29 ›› Issue (4) : 371-374.
Measurement of orbital volume in zygomaticomaxillary complex fractures and its clinical significance
Objective To calibrate the variations of orbital volume of zygomaticomaxillary complex fracture patients, and get the accordance to recover the normal orbital volume and shape, based on three-dimensional reconstruction and computer software technique. Methods 18 patients with the zygomaticomaxillary complex fractures and endophthalmos were scanned by multiple spiral CT, and then, the Simplant analytic software was used to calibrate and compare statistically the intact and traumatized orbital volume. Results Traumatized orbital volume significantly enlarged in all patients, with a mean volume of (1.83±0.75) cm3 compared with the opposite intact orbit (P=0.000). For the males, the intact orbit volume was about (28.50±1.15) cm3, which was significant different with that of the females (23.57±1.31) cm3 (P=0.000). Conclusions The promptly measurement of orbital volume is helpful for making optimal operation plan, recovering accurately the original orbital volume, and avoiding the development of endophthalmos.
Zygomaticomaxillary complex fractures / Orbital volume / Three-dimensional reconstruction / Computer software technique
[1] Metzger MC, Schon R, Zizelmann C, et al. Semiautomatic procedure for individual preforming of titanium meshes for orbital fractures
[J].Plast Reconstr Surg, 2007, 119(3):969-976.
[2] Ramieri G, Spada MC, Bianchi SD,et al. Dimensions and volumes of the orbit and orbital fat in posttraumatic enophthalmos
[J].Dentomaxillofac Radiol, 2000, 29(5):302-311.
[3] Kolk A, Pautke C, Schott V, et al. Secondary post-traumatic enophthalmos:high-resolution magnetic resonance imaging compared with multislice computed tomography in postoperative orbital volume measurement
[J].J Oral Maxillofac Surg, 2007,65(10):1926-1934.
[4] Ploder O, OeckherM, Klug C, et al. Isolated fractures of the orbital floor
[J]. Mund Kiefer Gesichtschir,2005, 9(2): 95-100.
[5] Acer N, Sahin B, Ergur H, et al. Stereological estimation of the orbital volume: a criterion standard study
[J]. J Craniofac Surg,2009,20(3):921-925.
[6] Deveci M, Ozturk S, Sengezer M, et al. Measurement of orbital volume by a 3-dimensional software program: an experimental study
[J]. J Oral Maxillofac Surg, 2000,58(6):645-648.
[7] Fan X, Zhou H, Lin M, et al. Late reconstruction of the complex orbital fractures with computer-aided design and computer-aided manufacturing technique
[J]. J Craniofac Surg, 2007,18(3),665-673.
[8] Regensburg NI, Kok PH, Zonneveld FW, et al. A new and validated CT-based method for the calculation of orbital soft tissue volumes
[J]. Invest Ophthalmol Vis Sci,2008,49(5), 1758–1762.
[9] Tahernia A, Erdmann D, Follmar K, et al. Clinical implications of orbital volume change in the management of isolated and zygomaticomaxillary complex-associated orbital floor injuries
[J].Plast Reconstr Surg, 2009,123(3): 968-975.
[10]Cunningham LL, Peterson GP, Haug RH. The relationship between enophthalmos, linear displacement, and volume change in experimentally recreated orbital fractures
[J].J Oral Maxillofac Surg, 2005, 63 (8):1169-1173.
[11]王育新,唐友盛,史 俊,等.计算机辅助测量颧眶骨折术前后眶容积的临床意义
[J]. 口腔颌面外科杂志,2008,18(6):405-408.
[12]Ahn HB, Ryu WY, Yoo KW, et al. Prediction of enophthalmos by computer-based volume measurement of orbital fractures in a Korean population
[J]. Ophthal Plast Reconstr Surg,2008,24(1):36-39.
[13]Chau A, Fung K, Yip L, et al. Orbital development in Hong Kong Chinese subjects
[J]. Ophthalmic Physiol Opt,2004,24(5):436-439.
[14] Ji Y, Qian Z, Dong Y, et al. Quantitative morphometry of the orbit in Chinese adults based on a three-dimensional reconstruction method
[J]. J Anat,2010,217(5):501-506.
[15] 张智勇,张 益,安金刚.眼眶容积的计算机软件辅助三维CT测量
[J].中华整形外科杂志,2006,22,(5):328-330.
/
〈 |
|
〉 |