临床生物力学

锁定钢板内置和外置固定SandersⅡ型跟骨骨折的三维有限元分析

  • 杨攀 ,
  • 章莹 ,
  • 刘坚 ,
  • 肖进 ,
  • 叶林强
展开
  • 1.广州中医药大学,  广州   510006;     2.广州军区广州总医院骨科医院,  广州   510010;
    3.广州军区广州总医院,  广州   510010
杨攀(1989-),男,四川南充人,博士研究生,研究方向:数字骨科

收稿日期: 2014-03-26

  网络出版日期: 2014-12-04

基金资助

国家科技部863计划项目(SS2012AA022811)

Finite element analysis of the calcaneal fractures of Sanders type Ⅱ fixed with locking plates in the internal and external position

  • YANG Pan ,
  • ZHANG Ying ,
  • LIU Jian ,
  • XIAO Jin ,
  • XIE Lin-Jiang
Expand
  • 1. Guangzhou University of Chinese Medicine, Guangzhou 510006, China;2.Orthopaedics Hospital, Guangzhou General Hospital of Guangzhou Military Command of PLA, Guangzhou 510010, China;3. Guangzhou General Hospital of Guangzhou Military Command of PLA, Guangzhou 510010, China

Received date: 2014-03-26

  Online published: 2014-12-04

摘要

目的 通过三维有限元对锁定钢板内置和外置固定SandersⅡ型跟骨骨折的生物力学稳定性进行比较,为临床应用提供理论依据。 方法 建立SandersⅡ型跟骨骨折分别予以锁定钢板内置位固定和外置位固定的三维有限元模型,在相同条件下分别对锁定钢板两种不同固定模型加载,行线性有限元分析,分别计算两种固定模型的应力分布情况。  结果 在中立位载荷下两种固定模型跟骨骨折线最大位移均小于跟骨关节内骨折手术指征的骨折线分离或移位≥1 mm的标准;两种固定模型跟骨最大主应力峰值都主要位于跟骨结节周围皮质骨,均小于骨屈服强度95 Mpa;两种固定模型锁定钢板系统最大主应力峰值主要位于钢板中间部,均小于内固定失效强度225 MPa。  结论 锁定钢板内置与外置固定SandersⅡ型跟骨骨折,其生物力学稳定性都令人满意,而锁定钢板外置在临床上有着潜在的应用价值。

本文引用格式

杨攀 , 章莹 , 刘坚 , 肖进 , 叶林强 . 锁定钢板内置和外置固定SandersⅡ型跟骨骨折的三维有限元分析[J]. 中国临床解剖学杂志, 2014 , 32(6) : 716 -720 . DOI: 10.13418/j.issn.1001-165x.2014

Abstract

Objective To compare the biomechanical properties of the calcaneal fractures of Sanders type Ⅱ fixed with locking plates in the internal and external position using finite element(FE) analysis, and therefore to provide theoretic reference for clinic application.  Methods 3D FE model of the calcaneal fractures of Sanders type Ⅱ fixed with locking plates in the internal and external position was constructed. The two fixation models were loaded under the same condition,and 1inear finite element analysis was carried out.The stress distribution in the two fixation models was calculated respectively. Results  Under the neutral position load the maximum displacement of the fracture lines in the two fixation models were less than fracture lines displacement requirement greater than 1 mm;the peak value of the maximum principle stress of the calcaneus in the two fixation models,located mainly around the cortical bones of calcaneal tuberosity, were less than the yield strength of 95 Mpa; the peak value of the maximum principle stress of the locking plate in the two fixation models, mainly located in the middle section of the locking plate, were less than the internal fixation failure strength of 225 MPa. Conclusion The biomechanical stability is satisfactory for the treatment of the calcaneal fractures of Sanders type Ⅱ fixed with locking plates in the internal and external position.The latter have potential application in clinic compared with the former in the treatment of calcaneal fractures of Sanders type Ⅱ.

参考文献


[1]  张国柱,蒋协远,王满宜.外置解剖型跟骨锁定钢板治疗跟骨骨折的初步报告
[J].中华创伤骨科杂志,2010,12(8):741-745.

[2]  陈剑,丁晓,史风雷,等. 小切口跟骨锁定钢板外置治疗跟骨骨折
[J].中医正骨,2013,25(4):49-50.

[3] Illert T, Rammelt S, Drewes T, et al. Stability of locking and non-locking plates in an osteoporotic calcaneal fracturemodel
[J]. Foot Ankle Int,2011,32(3):307-313.

[4]  Sitthiseripratip K,Van Oosterwyck H,Vander Sloten J,et a1.Finite element study of trochanteric gamma nail for trochanterie fracture
[J].Med Eng Phys, 2003,25(2):99-106.

[5] Kobayashi E,Wang TJ,Doi H,et a1.Mechanical properties and corrosion resistance of Ti-6A1-7Nb alloy dental castings
[J].J Mater SciMater Med, 1998,9(10):567-574.

[6]  王一民, 张晟,王博炜,等.锁定钢板固定Sanders Ⅳ型跟骨骨折的有限元分析
[J].中华创伤骨科杂志, 2013,15(3):225-229.

[7]  郭宗慧,庞清江,刘江涛,等.载距突螺钉内固定治疗SandersⅡ型跟骨骨折的生物力学研究
[J].中华骨科杂志,2013,33(4):331-335.

[8]  Mesfar W, Shirazi-Adl A. Computational biomechanics of knee joint in open kinetic chain extension exercises
[J]. Comput Methods Biomech Biomed Engin, 2008,11(1):55-61.

[9] Zelle J, Van der Zanden AC, De Waal Malefijt M,et al.Biomechanical analysis of posterior cruciate ligament retaining high-flexion total knee arthroplasty
[J].Clin Biomech(Bristol, Avon),2009,24(10):842-829.

[10] 黄海晶, 马信龙, 马剑雄, 等. 正常与畸形愈合跟骨应力分布的比较研究
[J].中华骨科杂志, 2013,33(4):336-341.

[11]Potter MQ, Nunley JA. Long-term functional outcomes after operative treatment for intra-articular fractures of the Calcaneus
[J]. J Bone Joint Surg Am, 2009,91(8):1854-1860.

[12]Dickenson RP, Hutton WC, Stott JR. The mechanical properties of bone in osteoporosis
[J].J Bone Joint Surg Br,1981,63B(2):233-238.

[13]Buckley R,T0ugII S,McCormack R,et a1.Operative compared with nonoperative treatment of displaced intra-acticular calcaneal fractures:a prospective,randomized,controlled multicenter tfial
[J].J Bone Joint Surg Am,2002,84(10):1733-1744.

[14]Harvey EJ, Grujic L, Early JS,et a1.Morbidity associated with ORIF of intra-articular calcaneus fractures nsins a lateral approach
[J].Foot Ankle Int, 200l,22(11):868-873.

[15]Kloen P. Supercutaneous plating: use of a locking compression plate as an external fixator
[J].J Orthop Trauma,2009,23(1):72-75.

[16]Zhang G, Jiang X, Wang M. External fixation with supercutaneous     calcaneal locking plate for displaced intra-articular calcaneal    fractures
[J]. Foot Ankle Int, 2012,33(12):1113-1118.

Options