穿支血管蒂螺旋桨皮瓣蒂部血管扭转的非线性有限元模拟研究
收稿日期: 2013-09-09
网络出版日期: 2014-04-21
基金资助
国家自然科学基金(81271993)
Nonlinear finite element simulations of perforator vessels twist in perforator pedicled propeller flaps
Received date: 2013-09-09
Online published: 2014-04-21
目的 研究牵张力、伴行静脉数量和动静脉间距对穿支血管蒂螺旋桨皮瓣蒂部血管扭转的影响。 方法 应用LSDYNA软件建立穿支血管蒂三维非线性数字化模型,分3组进行实验:(1)等长和等张扭转;(2)血管蒂为1支和2支伴行静脉;(3)穿支动静脉间距分别在0、2、4、6 mm的情况下扭转。3组实验均从0°扭转至180°,通过血管最窄处横截面积变化,反映血管的通畅性。 结果 (1)等张扭转组血管蒂通畅程度明显大于等长扭转组;(2)1支管腔通畅程度大于2支,但2支静脉的管腔截面积之和仍大于1支;(3)穿支动静脉间距加大,管腔的狭窄程度也逐渐增加。 结论 (1)在血管蒂扭转的同时施加牵张力,将使血管的通畅性明显降低;(2)在穿支血管蒂螺旋桨皮瓣中, 2支伴行静脉的通畅性仍较1支为好;(3)穿支动静脉间距越大,扭转后绞窄越明显,甚至发生管腔闭塞。
陶友伦 , 张世民 , 陈文龙 , 张英琪 , 王欣 , 刘天一 , 马飞 , 顾玉东 . 穿支血管蒂螺旋桨皮瓣蒂部血管扭转的非线性有限元模拟研究[J]. 中国临床解剖学杂志, 2014 , 32(2) : 201 -205 . DOI: 10.13418/j.issn.1001-165x.2014
Objectives To investigate the effects of some parameters (tension-stretch, number of concomitant vein and interval between perforator artery and vein) on the vascular patency after twisting of the perforator pedicle in perforator pedicled propeller flaps. Methods LSDYNA software was used to establish a three-dimensional nonlinear digital model of perforator consisting of an artery and a vein with both ends fixed. In Group 1, the perforator pedicle was twisted in isometric and isotonic conditions; in Group 2, the perforator pedicle was twisted with 1 concomitant vein and 2 concomitant veins; and in Group 3, the pedicle was twisted in the interval of 0 mm, 2 mm, 4 mm and 6 mm between the perforator artery and vein, respectively. In each group, all perforator pedicles were rotated from 0° to 180°. The effective strain was obtained to represent the perforator patency. Results In Group 1, the effective strain of perforator pedicle in isotonic condition was smaller (more patency) than that in isometric; in Group 2, the effective strain of perforator pedicle with 2 concomitant veins was larger than that of 1 concomitant vein, but the total lumen open area of the 2 veins was still greater than 1 vein; in Group 3, the effective strain of perforator pedicle increased (less patency) as the interval increased from 0 mm to 6 mm. Conclusions (1) The patency of the twisted perforator vessels is decreased when tension-stretching is added on the perforator pedicle. (2) The venous patency of preserving 2 concomitant veins is better than that of only 1 vein after the perforator-pedicle torsion. (3) The patency of the perforator is decreased when the interval between perforator artery and vein is increased.
[1] 陶友伦,张世民.穿支血管蒂螺旋桨皮瓣
[J].中国临床解剖学志,2011,29(06):606-608.
[2] Chang SM, Zhang F, Yu GR, et al. Modified distally based peroneal artery perforator flap for reconstruction of foot and ankle
[J]. Microsurgery, 2004, 24(6): 430-436.
[3] Hyakusoku H, Ogawa R, Oki K, et al. The perforator pedicled propeller (PPP) flap method: report of two cases
[J]. J Nippon Med Sch, 2007, 74(5):367-371.
[4] Teo TC. The propeller flap concept
[J]. Clin Plast Surg, 2010, (37): 615-626.
[5] Masia J, Moscatiello F, Pons G, et al. Our experience in lower limb reconstruction with perforator flaps
[J]. Ann Plast Surg, 2007, 58(5): 507-512.
[6] Schaverien M, Saint-Cyr M. Perforators of the lower leg: analysis of perforator locations and clinical application for pedicled perforator flaps
[J]. Plast Reconstr Surg, 2008,122(1):161-170.
[7] Gir P, Cheng A, Oni G. Pedicled-perforator (propeller) flaps in lower extremity defects: a systematic review
[J]. J Reconstr Microsurg, 2012, 28(9):595-601.
[8] Nelson JA, Fischer JP, Brazio PS, et al. A review of propeller flaps for distal lower extremity soft tissue reconstruction: Is flap loss too high
[J]? Microsurgery, 2013 Jul 16.
[Epub ahead of print]
[9] Lee HJ, Lim SY, Pyon JK, et al. The influence of pedicle tension and twist on perforator flap viability in rats
[J]. J Reconstr Microsurg, 2011, 27(7):433-438.
[10]Topalan M, Bilgin SS, Ip WY. Effect of torsion on microarterial anastomosis patency
[J]. Microsurgery, 2003, 23(1):56-59.
[11]Demirseren ME, Yenidunya MO, Yenidunya S. Island rat groin flaps with twisted pedicles
[J]. Plast Reconstr Surg, 2004, 114(5): 1190-1194.
[12]Chang CH, Lim SY, Pyon JK. The influence of pedicle length on the viability of twisted perforator flaps in rats
[J]. J Reconstr Microsurg, 2009, 25(9):533-538.
[13]Wong CH, Cui F, Tan BK, et al. Nonlinear finite element simulations to elucidate the determinants of perforator patency in propeller flaps
[J]. Ann Plast Surg, 2007, 59(6): 672-678.
[14]Horng SY, Chen CK, Lee CH. Quantitative relationship between vascular kinking and twisting
[J]. Ann Vasc Surg, 2010, 24(8): 1154-1155.
[15]LS-DYNA Keyword User's Manual, Version 970
[M]. Livermore Software Technology Corporation, pril 2003.
[16]Al-Sukhun J, Penttil? H, Ashammakhi N. Microvascular stress analysis: Part II. Effects of vascular wall compliance on blood flow at the graft/recipient vessel junction
[J]. J Craniofac Surg, 2011, 22(3):883-887.
[17]Hanasono MM, Kocak E, Ogunleye O. One versus two venous anastomoses in microvascular free flap surgery
[J]. Plast Reconstr Surg, 2010, 126(5):1548-1557.
[18]Rozen WM, Whitaker IS, Acosta R. One versus two venous anastomoses in microvascular free flap surgery
[J]. Plast Reconstr Surg, 2011, 127(6):2514-2515.
[19]Dediol E, Uglesic V, Knezevic P. Single versus double venous microvascular anastomoses
[J]. Plast Reconstr Surg, 2011,127(6):2513.
[20]陈亮,顾玉东.显微外科基础理论
[M]// 顾玉东. 显微外科基本理论与操作. 第2版. 上海:复旦大学出版社,2010:19.
/
| 〈 |
|
〉 |