腰椎“人”字嵴顶点定位的三维CT影像研究

杨敬, 常鑫, 王强, 朱伟, 赵小魁, 杜心如

中国临床解剖学杂志 ›› 2013, Vol. 31 ›› Issue (1) : 60-63.

中国临床解剖学杂志 ›› 2013, Vol. 31 ›› Issue (1) : 60-63.
断层影像解剖

腰椎“人”字嵴顶点定位的三维CT影像研究

  • 杨敬1, 常鑫2, 王强1, 朱伟1, 赵小魁1, 杜心如3
作者信息 +

Imaging anatomy of location of top point of '∧' shape crest by using three-dimensional CT

  • YANG Jing1,CHANG Xin2,WANG Qiang1,ZHU Wei1,DU Xin-ru3
Author information +
文章历史 +

摘要

目的 基于CT断层图像重建腰椎模型及三维可视化的方法研究如何确定腰椎“人”字嵴顶点,指导临床应用。  方法 将30例腰椎CT导入Mimics 10.01获得骨骼三维几何模型。在三维重建模型上应用“人”字嵴顶点法、“人”字嵴顶点上法及“人”字嵴顶点下法模拟置钉,测量进钉点至椎弓根轴线的距离及其与上下缘、内外缘的位置关系.比较3种方法在腰椎各节段的差异及优缺点。  结果 在L1~5,“人”字嵴顶点法的进钉点到椎弓根轴线距离小于它其两种方法。说明该确定方法较为理想。同时随着椎体序列的增加逐渐低于椎弓根轴线。  结论 在此基础上模拟的3种确定“人”字嵴顶点的方法与椎弓根轴线的解剖关系存在较大差异;“人”字嵴顶点定位法的钉道与椎弓根纵行中心线最近。

Abstract

Objective to study three methods of lumbar pedicle placement in different level based on CT tomographic image reconstruction model in order to determine the location of "∧" shape crest of the Lumbar vertebra and provide objective basis. Methods In 30 cases of lumbar CT three-dimensional reconstruction model, the placement of the screw was simulated, using the method of the "∧ "shape crest, the method of above the "∧ "shape crest and the method of below the "∧ "shape crest, the distance between screw entry point and the pedicle axis was measured, and the anatomic relationship between the upper and lower edges, the internal and the external edges was studied. Differences, advantages and disadvantages of three methods at each segment of lumbar were analysed. Results The anatomic relationship between  "∧ "shape crest and lumbar pedicle was different in the three methods. The distance between "∧ "shape crest and the pedicle axis was shortest in the median sagittal plane, but was slightly higher than pedicle axis in the L1, and was slightly lower than the horizontal axis in L5 . The Upper "∧ " shape crest was located above the pedicle axis. Only in 2 cases Upper "∧ " shape crest was lower than the pedicle axis in the L5. Conclusion in the lumbar pedicle screw fixation, "∧ "shape crest method is safe and reliable, applicable to L1~ L5. But in L1 the screw in the median sagittal plane is slightly higher than the pedicle axis, and was slightly lower the axis of the pedicle in L5 .

关键词

&ldquo / 人&rdquo / 字嵴 / 椎弓根螺钉 / CT / 三维重建

Key words

"&and / "shape crest / Pedicle screw / CT / Three dimensional reconstmctio

引用本文

导出引用
杨敬, 常鑫, 王强, 朱伟, 赵小魁, 杜心如. 腰椎“人”字嵴顶点定位的三维CT影像研究[J]. 中国临床解剖学杂志. 2013, 31(1): 60-63
YANG Jing, CHANG Xin, WANG Jiang, SHU Wei, DIAO Xiao-Kuai, DU Xin-Ru. Imaging anatomy of location of top point of '∧' shape crest by using three-dimensional CT[J]. Chinese Journal of Clinical Anatomy. 2013, 31(1): 60-63
中图分类号: R681         

参考文献


[1]  Weinstein JN, Spratt KF, Spengler D,et al. Spinal pedicle fixation:Reliability and validity of roentgenogram-based assessment and surgical factors of successful screw placement
[J]. Spine,1988,13(9): 1012-1018.

[2]  杜心如,叶启彬,赵玲秀,等.腰椎“人”字嵴顶点椎弓根螺钉进钉方法的解剖学研究
[J]. 中国临床解剖学杂志,2002, 20(2): 86-88.

[3]  杜心如,赵玲秀,叶启彬,等.选择腰椎椎弓根螺钉长度的放射解剖学研究
[J].中国临床解剖学杂志,2002,20(1):15-17.

[4]  杜心如,赵玲秀,张一模,等.腰椎“人”字嵴顶点毗邻结构的观察及其临床意义
[J].中国脊柱脊髓杂志,2001,11(2):89-01.

[5]  樊继宏,钟世镇,焦培峰, 等.以有限元分析为目标的Mimics颈椎建模的新思路
[J]. 中国临床解剖学杂志,2011, 29(2): 222-224.

[6]  杜心如, 赵玲秀,张一模,等.腰椎“人”字嵴顶点椎弓根螺钉进钉方法的解剖学研究
[J]. 中国临床解剖学杂志,2002, 20(2): 86-88.

[7] Kadoury S, Cheriet F, Laporte C, et al. A versatile 3D reconstruction system of the spine and pelvis for clinical assessment of spinal deformities.
[J]. Med Biol Eng Comput,2007,45(6): 591-602.

[8] Schmitt J, Lengsfeld M, Alter P, et al. Use of voxel-oriented femur models for stress analysis. Generation, calculation and validation of CT-based FEM models
[J]. Biomed Tech (Berl),1995, 40(6): 175-181.

[9] Kling-Petersen T, Rydmark M. Modeling and modification of medical 3D objects. The benefit of using a haptic modeling tool
[J]. Stud Health Technol Inform,2000, 70: 162-167.

[10]李兵,姜保国,傅忠国,等. CT重建椎弓根轴线投影点定位研究
[J].中国脊柱脊髓杂志,2003, 13(9): 551-554.


Accesses

Citation

Detail

段落导航
相关文章

/