水平带状钢板治疗胫骨平台后外侧象限骨折的生物力学研究
胡孙君,张世民,李双,杜守超,马卓,熊文峰,张英琪
中国临床解剖学杂志 ›› 2018, Vol. 36 ›› Issue (1) : 77-81.
水平带状钢板治疗胫骨平台后外侧象限骨折的生物力学研究
Horizontal belt plate fixation for treating the isolated posterolateral tibial plateau fracture:a biomechanical study
目的 比较胫骨平台后外侧象限骨折不同内固定方式的力学稳定性效果。 方法 采用Synbone人工合成胫骨18个,切割构建孤立的胫骨平台后外侧象限骨折模型,随机分为3组,分别采用外侧水平带状钢板固定、外侧低切迹解剖锁定钢板固定、后侧直形重建钢板固定。将固定好的骨折模型置于万能水压材料测试机进行测试,分别进行静态加载、疲劳测试和极限加载,检测骨块的相对空间位移。 结果 以10 mm/min加载至总载荷1050 N,重复加载10000次后,带状钢板组骨折块的纵向位移(2.77±1.79) mm,外侧锁定钢板组的纵向位移为(2.69±1.14) mm;后方重建钢板组骨折块的纵向位移为(1.62±0.60) mm,组间差异无统计学意义(P>0.05)。施加载荷到骨或内固定的结构破坏后,带状钢板组的极限支撑力为(2055±263) N,外侧锁定钢板组的为(1968±209)N,后方重建钢板组的极限支撑力为(2272±130) N,组间差异具有显著的统计学意义(P<0.05)。 结论 治疗孤立的胫骨平台后外侧象限骨折,侧方带状钢板水平固定能取得满意的效果。
Objective To compare and analyze the biomechanical stability of 3 different fixations for the posterolateral tibial plateau fracture. Methods The posterolateral shearing fracture models were created in 18 synthetic tibia(Synbone) and randomly assigned into 3 groups.The fractures were fixed by horizontal belt plate (Group A), lateral low-profile anatomical LCP (Group B) and posterior reconstructive plate(Group C). Vertical displacements of the posterolateral fragments and failure loads were measured under axial loads including static loading test (from 300 N to 1050 N), fatigue loading test and damage loading teat. Results The vertical displacements in groups A,B,and C were respectively (2.77±1.79)mm, (2.69±1.14)mm, and (1.62±0.60)mm under fatigue loading test, the total load 1050N with 10 mm/min and repeat load 10000 times.There was no significant difference between the groups (P>0.05). After the damage loading test, the final force in groups A,B,and C were respectively (2055±263) N, (1968±209) N and (2272±130) N, and there was significant difference among the groups (P<0.05). Conclusion Horizontal belt plate fixation for isolated posterolateral tibial plateau fracture can bring sufficient stability for the posterolateral fragment.
胫骨平台 / 后外侧平台 / 平台骨折 / 钢板内固定 / 疗效 / 生物力学
Tibial plateau; Posterolateral plateau fracture; Plate internal fixation; Outcome;  / Biomechanics
[1] Luo CF,Sun H,Zhang B,et al. Three-column fixation for complex tibial plateau fractures [J]. J Orthop Trauma,2010,24(11):683-692.
[2] 胡孙君,张英琪,张世民. 胫骨平台后外侧骨折的治疗进展 [J]. 中华创伤骨科杂志,2014,16(10):898-901.
[3] 毛玉江,张伯松,公茂琪,等. 后内和后外侧入路治疗胫骨平台后髁骨折的疗效分析 [J]. 中华创伤骨科杂志, 2014,16(7):625-628.
[4] He X,Ye P,Hu Y,et al. A posterior inverted L-shaped approach for the treatment of posterior bicondylar tibial plateau fractures [J]. Arch Orthop Trauma Surg,2013,133(1):23-28.
[5] Hu SJ, Chang SM, Zhang YQ, et al. The anterolateral supra-fibular-head approach for plating posterolateral tibial plateau fractures: A novel surgical technique [J]. Injury, 2016, 47(2):502-507.
[6] Chang SM,Zheng HP,Li HF,et al. Treatment of isolated posterior coronal fracture of the lateral tibial plateau through posterolateral approach for direct exposure and buttress plate fixation [J]. Arch Orthop Trauma Surg, 2009, 129(7):955-962.
[7] Xiang G,Zhi-Jun P,Qiang Z,et al. Morphological characteristics of posterolateral articular fragments in tibial plateau fractures [J]. Orthopedics,2013,36(10):e1256-e1261.
[8] Li Q,Zhang YQ,Chang SM. Posterolateral fragment characteristics in tibial plateau fractures [J]. Int Orthop,2014,38(3):681-682.
[9] Garner MR, Warner SJ, Lorich DG. Surgical Approaches to Posterolateral Tibial Plateau Fractures[J]. J Knee Surg, 2016, 29(1):12-20.
[10]Chen H, Wu L. Surgical options for posterior tibial plateau fracture [J]. Int J Clin Exp Med, 2015, 8(11):21421-21427.
[11]Chang SM. Selection of surgical approaches to the posterolateral tibial plateau fracture by its combination patterns [J]. J Orthop Trauma,2011,25(3): e32-e33.
[12]胡孙君,张世民,张英琪,等. 胫骨平台后外侧象限骨折手术入路的深层解剖:后外侧与后内侧对比 [J]. 中国临床解剖学杂志,2015,33(5):497-501.
[13]Chen WT,Zhang YQ,Chang SM. Posterolateral approach for plating of tibial plateau fractures and the risk of injury to the anterior tibial vessels [J]. J Orthop Trauma,2013,27(9): e228-229.
[14]Huang YG,Chang SM. The posterolateral approach for plating tibial plateau fractures: problems in secondary hardware removal [J]. Arch Orthop Trauma Surg,2012,132(5):733-734.
[15]Chen HW, Zhou SH, Liu GD, et al. An extended anterolateral approach for posterolateral tibial plateau fractures [J]. Knee Surg Sports Traumatol Arthrosc, 2015, 23(12):3750-3755.
[16]Yu B,Han K,Zhan C,et al. Fibular head osteotomy: a new approach for the treatment of lateral or posterolateral tibial plateau fractures [J]. Knee,2010,17(5):313-318.
[17]储旭东,朱建平,蔡福金,等. 胫骨平台后外侧髁骨折腓骨小头上入路设计及临床应用 [J]. 中华骨科杂志,2012,32(12):1145-1150.
[18]Giordano V, Schatzker J, Kfuri M. The "Hoop" Plate for Posterior Bicondylar Shear Tibial Plateau Fractures: Description of a New Surgical Technique [J]. J Knee Surg, 2017, 30(6):509-513.
[19]Cho JW, Samal P, Jeon YS, et al. Rim plating of posterolateral fragment (PLF) through modified anterolateral approach in tibial plateau fractures [J]. J Orthop Trauma, 2016, 30(11):e362-e368.
[20]Cho JW, Kim J, Cho WT, et al. Approaches and fixation of the posterolateral fracture fragment in tibial plateau fractures: a review with an emphasis on rim plating via modified anterolateral approach [J]. Int Orthop,2017,41:1887-1897.
[21]Zhang W, Luo CF, Putnis S, et al. Biomechanical analysis of four different fixations for the posterolateral shearing tibial plateau fracture [J]. Knee, 2012, 19(2):94-98.
/
〈 |
|
〉 |