The precision of the 2D/3D registration techniques in measuring the cervical intervertebral foramen morphology

ZHANG Xin-tao1, YE Qiang1, LI Jian-yi2, PENG Peng2, LI Shao-Lin1   

  1. 1. Department of Radiology, The Third Affiliate Hospital, Southern Medical University, Guangzhou 510630,China;  2.Department of Anatomy, Guangdong Provincial Key Laboratory of Medical Biomechanics, Southern Medical University, Guangzhou 510515,China
  • Received:2016-04-11 Online:2016-09-25 Published:2016-10-14

摘要:

目的 探讨基于2D/3D配准技术测量离体颈椎标本椎间孔形态学的精度。  方法 获取16具颈椎离体标本的螺旋CT影像,通过三维重建获得相应标本的三维模型。然后改变标本的体位,再次行CT扫描并分别拍摄各具离体标本正侧位X线平片,采用2D/3D图像配准技术还原拍摄平片时颈椎的三维位置。利用Rapidform XOR3软件测量配准前与配准后C2/3至C6/7双侧的椎间孔面积、前后径和上下径。  结果 共测得椎间孔的面积、前后径和上下径各158个,经配对样本t检验,配准后椎间孔的面积、前后径、上下径与配准前相比较,结果无显著性差异(P>0.05);椎间孔面积的准确度为96.77%、精确度为(1.27±1.16)mm2,前后径的准确度为94.35%、精确度为(0.30±0.27)mm,上下径的准确度为96.14%、精确度为(0.32±0.28)mm。  结论 应用2D/3D配准技术测量颈椎间孔的形态学参数具有较高的准确度和精确度。

关键词: 颈椎, 椎间孔, 2D/3D配准

Abstract:

Objective To investigate the 2D/3D registration techniques in measurement accuracy of cervical intervertebral foramen morphology in specimens. Method Spiral CT images from 16 cervical specimens were collected to obtain a three-dimensional model through three-dimensional reconstruction. CT scan and lateral radiography with each isolated specimens after changed the position of the specimen were performed. 2D/3D image registration techniques were used to restore the cervical spine’s three-dimensional position where we had taken the X-rays. The bilateral foramen area, anteroposterior diameter and vertical diameter from C2/3 to C6/7 before and after registration were measured using Rapidform XOR3. Results The number of the foramen area, anteroposterior diameter and vertical diameter were measured were 158. Compared with the pre-registration, the registration area of the intervertebral foramen, anteroposterior diameter, and vertical diameter showed no significant difference (P>0.05) by paired samples t-test. The accuracy of the intervertebral foramen area was 96.77%, with a precision of (1.27±1.16) mm2, the accuracy of the anteroposterior diameter was 94.35% with a precision of (0.30±0.27) mm, the diameter of the upper and lower accurate degree was 96.14% with a precision of (0.32±0.28) mm. Conclusion Application of 2D/3D registration techniques to measure cervical intervertebral morphological parameters was high in accuracy and precision.

Key words: Cervical spine, Intervertebral foramen, 2D/3D registration