Finite element analysis of the throwing fracture of humerus fixed with locking compression plates and interlocking intramedullary nails

  • ZHENG Xiang ,
  • ZHANG Ying ,
  • CHAN Yong-Xin ,
  • XIE Hui-Bin ,
  • GUO Xiao-Ze ,
  • SHU Chang-Rong
Expand
  • 1.Postgraduate Institute, Southern Medical University, Guangzhou 510515, China; 2.Orthopaedics Hospital, General Hospital of Guangzhou Military Region, Guangzhou 510010, China; 3.Department of Orthopedics, 173 Clinical Center of the 421st Hospital of PLA,Huizhou 516008, China

Received date: 2014-07-11

  Online published: 2015-04-21

Abstract

Objective    To explore and compare the biomechanical properties of the throwing fracture of humerus fixed with locking compression plates and interlockingintramedullary nails using finite element analysis, and therefore to provide theoretic reference for clinic application.   Methods    3D FE models of the throwing fracture of humerus fixed with locking compression plates in anterolateral and posterior, retrograde and antegrade interlocking intramedullary nails were developed. Each mode was tested in axial compression, bending and anticlockwise torsion. The von-Mises and total deformation of internal fixities, humerus and fracture end were used to compare.    Results    The maximum stress of the anterolateral plate placement was smaller than the posterior plate placement. Under compression loading, the maximum stress of the retrograde intramedullary nail was smaller than the antegrade intramedullary nail group while the opposite results were obtained under the bending and anticlockwise torsion loadings. The maximum deformation of humerus of locking compression plate groups was smaller than the intramedullary nail groups, the anterolateral plate group was greater than the posterior group, and the antegrade intramedullary nail group was greater than the retrograde group. The stress distribution of fracture end of the locking compression plate groups was more uniform than the interlocking nail groups and had a larger maximum stress.  Conclusions   The throwing fracture of humerus fixed with locking compression plate is more stable and the stress distribution is more uniform than  that fixed interlocking intramedullary nail. Locking compression plate in posterior placement is more stable than the anterolateral placement but have a larger maximum stress. Fixation with retrograde intramedullary nail is more stable than that with the antegrade intramedullary nail.

Cite this article

ZHENG Xiang , ZHANG Ying , CHAN Yong-Xin , XIE Hui-Bin , GUO Xiao-Ze , SHU Chang-Rong . Finite element analysis of the throwing fracture of humerus fixed with locking compression plates and interlocking intramedullary nails[J]. Chinese Journal of Clinical Anatomy, 2015 , 33(2) : 213 -217 . DOI: 10.13418/j.issn.1001-165x.2015

References


[1]  王乃斌. 投掷骨折综述
[J]. 人民军医,1965,(7):36-38.

[2]  樊黎霞,丁光兴,费王华,等. 基于CT图像的长管骨有限元材料属性研究及实验验证
[J]. 医用生物力学, 2012, 28(1):102-108.

[3] Paller DJ. A three-dimensional comparison of intramedullary nail constructs for osteopenic supracondylar femur fractures
[J]. Orthop Trauma, 2013, 27(2):93-99.

[4]  Lin CL, Lin YH, Chen AC. Buttressing angle of the double-plating fixation of a distal radius fracture: a finite element study
[J]. Med Biol Eng Comput, 2006,44(8): 665-673.

[5] 宁聪琴,周玉. 医用钛合金的发展及研究现状
[J]. 材料科学与工艺,2002,12(1):100-106.

[6] Sabalic S, Kodvan J,Pavic A. Comparative study of three models of extra-articular distal humerus fracture osteosynthesis using the finite element method on an osteoporotic computational model
[J]. Injury, 2013,44( 3 Suppl): 56-61.

[7] Lamdan R, Liebergall M, Gefen A,et al. Pediatric supracondylar humerus fractures: effect of bone-implant interface conditions on fracture stability
[J]. J Child Orthop, 2013,7(6): 565-569.

[8]  梁旭,杨铁毅,张岩,等. 胫骨平台后外侧1/2骨折不同内固定方式的有限元分析
[J]. 中国矫形外科杂志,2013,21(20):1353-1358.

[9]  朱昌荣,章莹,郭晓泽,等. 重建钢板前置和上置固定锁骨中段斜形骨折的有限元分析
[J]. 中国临床解剖学杂志,2013,31(1):104-107.

[10]田竞,李秀岩,周大鹏,等. 髓内钉与干骺端锁定加压钢板治疗肱骨投弹骨折的疗效比较
[J]. 中国骨与关节外科,2012,5(2):143-147.

[11] Gerwin M, Hotchkiss R, Weiland A. Alternative operative exposures of the posterior aspect of the humeral diaphysis with reference to the radial nerve