Study of technical parameters of C1 lateral screws placement in Jefferson-fracture reduction plate

JIA Gong, LIN Hong-Heng, HU Guo-Qiang, HE Xiao-Hua, YIN Qiang-Shui, WANG Zhi-Yun, HU Dun-Jie

Chinese Journal of Clinical Anatomy ›› 2012, Vol. 30 ›› Issue (6) : 641-645.

Chinese Journal of Clinical Anatomy ›› 2012, Vol. 30 ›› Issue (6) : 641-645.

Study of technical parameters of C1 lateral screws placement in Jefferson-fracture reduction plate

  • XIA Hong1, LIN Hong-heng1, XU Guo-qing2, HE Xiao-hua2, YIN Qing-shui1, WANG Zhi-yun1, XU Jun-jie1
Author information +
History +

Abstract

Objective To clarify the technical parameters of C1 lateral mass screw in anterior Jefferson-fracture reduction plate.  Methods Anatomic structure of C1 lateral mass using 1-mm CT scans were measured with MIMICS software in 80 C1 lateral mass of 40 cases. 2 entry points were selected for superior and inferior screw placement and screws (2.5mm in diameter) , and simulation procedure was performed at these entry points. Length, angle of screw and relation with adjacent anatomical structures were recorded. Results Distance from medial wall of vertebral artery hole to midline of atlas was 23.2 mm. Distance between medial wall of posterior arch junction with lateral mass and midline was 13.2 mm, and from entry point of superior screw to anterior edge of superior articular and midline were 6.2mm, 20.0mm respectively. The length of superior screw was 21.5 mm and the range of sagittal angulation was upward 1.5° to downward 11.6°. Distance from entry point of inferior screw to anterior edge of inferior articular was 8.9mm. Length of inferior screw was 15.2mm. The largest downward angulation for inferior screw was 20.7°. Distance from medial wall of vertebral hole to inferior screw was 1.9mm. The area of lateral mass (17.6~23.2) mm away from midline of atlas is relative safe for screw placement.  Conclusions It is feasible to place C1 lateral mass screws (superior and inferior screw) in anterior Jefferson-fracture reduction plate. Making final decision of entry points and screw direction must depend on preoperative 3-dimensional CT evaluation. According to our research, the angulation of superior screw below turn to downward, and the angulation of inferior screw turn to inside were recommended.

Key words

CT scans / Atlas / Jefferson fracture / Internal fixation / MIMICS software

Cite this article

Download Citations
JIA Gong, LIN Hong-Heng, HU Guo-Qiang, HE Xiao-Hua, YIN Qiang-Shui, WANG Zhi-Yun, HU Dun-Jie. Study of technical parameters of C1 lateral screws placement in Jefferson-fracture reduction plate[J]. Chinese Journal of Clinical Anatomy. 2012, 30(6): 641-645

References


[1] Hadley MN, Dickman CA, Browner CM, et al. Acute traumatic atlas fractures: management and long term outcome
[J]. Neurosurgery, 1988, 23(3):31-35.

[2] Levine AM, Edwards CC. Treatment of injuries in the C1-C2 complex
[J]. OrthopClinNorthAm, 1986, 17(1):31-44.

[3] Hein C,Richter HP,Rath SA. Atlantoaxial screw fixation for the treatment of isolated and combined unstable Jefferson fractures-experiences with 8 patients
[J]. Acta Neurochir, 2002, 144(11):1187-1192.

[4]  Cattrvsse E, Barbero M, Kool P, et al. 3D morphometry of the transverse and alar ligaments in the occipitoatlantoaxial complex: an in vitro analysis
[J]. Clin Anat, 2007, 20(8):892-898.

[5]  焦云龙,尹庆水.JeRP治疗不稳定型Jefferson骨折的应用解剖及生物力学评价
[J] . 中国临床解剖学杂志,2009,27(3):340-343.

[6]  廖穗祥,夏虹.寰椎骨折前路复位内固定系统的研制及相应部位的解剖学测量
[J].实用医学杂志,2007,23(24):3815-3818.

[7]  夏虹, 钟世镇,刘景发,等. 寰椎侧块后路螺钉固定的可行性研究
[J].中国矫形外科杂志,2002,10(9):888-891.

[8]  马向阳,钟世镇,刘景发,等.寰椎后弓侧块螺钉固定的解剖学测量
[J].中国脊柱脊髓杂志,2004,14(1):23-25.

[9]  严望军,黄会龙,周许辉,等.寰枕关节后路经关节螺钉固定的解剖学
[J].解剖学杂志,2005,28(3):343-345.