Digital anatomical research on the maximum screw channel of the percutaneous retrograde suprapubic  branch

Yang Demeng, He Jinjian, Zhang Mingkun, Song Jinhang, Li Shaojuan, Ren Tianning, Yan Hanxiao, Hu Zhenhua, Peng Dandan, Zhu Shuliang, Hou Likang, Han Muyu, Chen Zhiguo

Chinese Journal of Clinical Anatomy ›› 2024, Vol. 42 ›› Issue (6) : 644-648.

PDF(2985 KB)
PDF(2985 KB)
Chinese Journal of Clinical Anatomy ›› 2024, Vol. 42 ›› Issue (6) : 644-648. DOI: 10.13418/j.issn.1001-165x.2024.6.06

Digital anatomical research on the maximum screw channel of the percutaneous retrograde suprapubic  branch

  • Yang Demeng1, He Jinjian2, Zhang Mingkun2, Song Jinhang2, Li Shaojuan2, Ren Tianning2, Yan Hanxiao2, Hu Zhenhua2, Peng Dandan2, Zhu Shuliang2, Hou Likang2, Han Muyu2, Chen Zhiguo3*
Author information +
History +

Abstract

Objective   To construct a 3D model of the pelvis, simulate the process of suprapubic screw placement, and determine the parameters of the largest channel for retrograde suprapubic screw placement.    Methods    Pelvic CT scan data of 50 adults were collected from the Imaging Center of Pingxiang People's Hospital from December 2020 to December 2022. This data was imported into Mimics 20.0 software to reconstruct the 3D pelvic model and simulate screw placement. The placement process was as follows: (1) The axis of the suprapubic screw channel was determined, a small-diameter virtual cylinder was inserted; (2) The diameter of the virtual cylinder was increased until it didn't break through the pubic body, suprapubic ramus and acetabulum, considering it as the largest screw channel; (3) The length and diameter of the largest screw channel, the angle of the screw axis with the sagittal and transverse planes were measured. Results   The ranges of the largest channel length were: male right (107.26±7.58) mm, male left (106.96±11.01) mm, female right (102.34±8.30) mm, female left (103.30±10.05) mm; the range of largest channel diameter were: male right (8.10±0.61) mm, male left (8.05±0.66) mm, female right (6.57±0.77) mm, female left (6.48±0.61) mm. There was no significant difference in the maximum length of the screw channel and the included angle with the cross section between male and female and between the left and right sides (P>0.05). There was no significant difference in the maximum diameter between the left and right sides (P>0.05), but the difference between male and female was statistically significant (P<0.001).   Conclusions   The average diameter and length of male in maximum screw channel are 8.07 mm and 107.11 mm, respectively. The average diameter and length of female are 6.50 mm 102.82 mm, respectively. This study can provide anatomical reference for percutaneous retrograde suprapubic branch screw fixation and help clinicians choose suitable surgical screws.

Key words

Superior pubic ramus fracture /   /   / Retrograde superior pubic ramus screw /   /   / Digital anatomy

Cite this article

Download Citations
Yang Demeng, He Jinjian, Zhang Mingkun, Song Jinhang, Li Shaojuan, Ren Tianning, Yan Hanxiao, Hu Zhenhua, Peng Dandan, Zhu Shuliang, Hou Likang, Han Muyu, Chen Zhiguo. Digital anatomical research on the maximum screw channel of the percutaneous retrograde suprapubic  branch[J]. Chinese Journal of Clinical Anatomy. 2024, 42(6): 644-648 https://doi.org/10.13418/j.issn.1001-165x.2024.6.06

References

[1]  袁欣华, 吴乃庆, 庞清江, 等. 逆行耻骨上支髓内螺钉固定应用解剖研究[J]. 中国骨与关节损伤杂志, 2006, 21(7): 539-541. DOI:10.3969/j.issn.1672-9935.2006.07.013.
[2]  Mouhsine E, Garofalo R, Borens O, et al. Percutaneous retrograde screwing for stabilisation of acetabular fractures[J].Injury, 2005, 36(11):1330-1336. DOI: 10.1016/j.injury.2004.09.016.
[3]  蒋巍, 张云坤, 徐南伟, 等. 骶髂关节脱位并耻骨联合分离、骨折的手术治疗 [J]. 医学临床研究, 2008, 25(5): 802-805 DOI: 10.3969/j.issn.1671-7171.2008.05.011.
[4]  Ye P, Lihai Z,William M, et al. Comparison of anterograde versus retrograde percutaneous screw fixation of anterior column acetabular fractures[J]. Int J Comput Assist Radiol Surg, 2016, 11(4):635-639.DOI:10.1007/s11548-015-1308-9.
[5]  Maria PR, Daniel W, Alex H. Minimal invasive surgical treatment of fragility fractures of the pelvis[J].Chirurgia (Bucur),2017,112(5):524-537.DOI:10.21614/chirurgia.112.5.524.
[6]  杨勇, 王磊, 王福川, 等. 耻骨上支骨折髓内螺钉进钉通道的数字解剖学研究[J].中国临床解剖学杂志, 2013, 31(4):397-401. DOI: 10.7666/d.y2104949.
[7] Ochs GB, Stuby MF, Ateschrang A,et al. Retrograde lag screw placement in anterior acetabular column with regard to the anterior pelvic plane and midsagittal plane-Virtual mapping of 260 three-dimensional hemipelvises for quantitative anatomic analysis[J].Injury, 2014, 45(10):1590-1598. DOI:10.1016/j.injury.2014.06.026.
[8]  Pijun Z, Jie T, Yonghui D, et al. A new navigational apparatus for fixation of acetabular posterior column fractures with percutaneous retrograde lagscrew: Design and application[J].Medicine, 2018,97(36):e12134. DOI:10.1097/MD.0000000000012134.
[9]  Him KC, Dennis CCC, Chun KI , et al. Three-dimensional navigation-guided percutaneous screw fixation for nondisplaced and displaced pelvi-acetabular fractures in a major trauma centre[J]. Int Orthop,2018,42(6):1387-1395. DOI:10.1007/s00264-017-3659-z.
[10]Theologis AA,  Burch S, Pekmezci M. Placement of iliosacral screws using 3D image-guided (O-Arm) technology and Stealth Navigation: comparison with traditional fluoroscopy[J]. Bone Joint J, 2016, 98-B(5): 696-702. DOI:10.1302/0301-620X.98B5.36287
[11]Richter P, Gebhard F, Dehner C, et al. Accuracy of computer-assisted iliosacral screw placement using a hybrid operating room[J].Injury, 2016, 47(2):402-407. DOI:10.1016/j.injury.2015.11.023
[12]杨德猛, 霍念慈, 周奥然, 等. 逆行耻骨上支通道螺钉两种入针点与生殖结构距离的解剖研究 [J]. 中国临床解剖学杂志, 2023, 41(2): 121-127. DOI:10.13418/j.issn.1001-165x.2023.2.01.
[13]Routt ML Jr, Simonian PT, Grujic L. The retrograde medullary superior pubic ramus screw for the treatment of anterior pelvic ring disruptions: a new technique[J]. Orthop Trauma, 1995, 9(1):35-44. DOI:10.1097/00005131-199502000-00006.
[14]Attias N,  Lindsey WR , Starr JA, et al. The use of a virtual three-dimensional model to evaluate the intraosseous space available for percutaneous screw fixation of acetabular fractures[J]. J Bone Joint Surg Br, 2005, 87(11):1520-1523. DOI:10.1302/0301-620X.87B11.16614.
[15]Shahulhameed A, Roberts SC, Pomeroy LC, et al. Mapping the columns of the acetabulum-Implications for percutaneous fixation[J].Injury, 2009, 41(4): 339-342. DOI:10.1016/j.injury.2009.08.004.
[16]Feng X, Feng J, Lin C, et al. Axial perspective to find the largest intraosseous space available for percutaneous screw fixation of fractures of the acetabular anterior column[J].Int J Comput Assist Radiol Surg, 2015, 10(8):1347-1353.DOI:10.1007/s11548-015-1149-6.
[17]Vivek T, Arvind K, Samarth M, et al. Morphometric analysis of the anterior column of the acetabulum and safety of intramedullary screw fixation for its fractures in Indian population: a preliminary report[J]. Int Orthop, 2020, 44(4): 655-664.DOI:10.1007/s00264-019-04428-5.
PDF(2985 KB)

Accesses

Citation

Detail

Sections
Recommended

/