Study on the correlation between measurement parameters of lumbar transverse process and height

He Zubin , Huang Junyang , Lu Jili, Li Weijian , Li Wei, Lu Xiaosheng, Zhang Meichao

Chinese Journal of Clinical Anatomy ›› 2021, Vol. 39 ›› Issue (3) : 259-262.

PDF(2323 KB)
PDF(2323 KB)
Chinese Journal of Clinical Anatomy ›› 2021, Vol. 39 ›› Issue (3) : 259-262. DOI: 10.13418/j.issn.1001-165x.2021.03.003

Study on the correlation between measurement parameters of lumbar transverse process and height

  • He Zubin 1 , Huang Junyang2 , Lu Jili2, Li Weijian1 , Li Wei1, Lu Xiaosheng3, Zhang Meichao4
Author information +
History +

Abstract

Objective To measure the structural parameters of transverse process of lumbar spine and analyze the correlation between those parameters and individual height, which  providing anatomic basis for the design the improved spinal correction system. Methods CT images of lumbar spine in 60 patients (30 cases in male and 30 cases in female) with different height were collected, then  three dimensional models of vertebral for the 60 patients were reconstructed by Mimics software. By these models, the length, width, thickness, coronal angle and horizontal plane angle of vertebral transverse process were measured and recorded. Spearson correlation analysis was performed by SPSS22.0 to understand the correlation between transverse process parameters and height. Results The correlation coefficient r value of the length of L2, L5 and the thickness of L5 were between 0.2~0.4. The correlation coefficient r value of the width of L1, L3 ,L4 and the thickness of L1 were between 0.4~0.6. The correlation coefficient r value of the thickness of L2, L3 ,L4 and the width of L2 were between 0.6~0.8. Conclusions The width and thickness of L1~4 transverse process are positively correlated with height. The length of transverse process is weakly correlated with height. While the horizontal angle and coronal angle of transverse process has no significant correlation with height. 

Key words

Transverse process parameters /  Height /  Correlation /  Mimics19.0 /  Improved spine correction system

Cite this article

Download Citations
He Zubin , Huang Junyang , Lu Jili, Li Weijian , Li Wei, Lu Xiaosheng, Zhang Meichao. Study on the correlation between measurement parameters of lumbar transverse process and height[J]. Chinese Journal of Clinical Anatomy. 2021, 39(3): 259-262 https://doi.org/10.13418/j.issn.1001-165x.2021.03.003

References

[1]  陆晓生, 黄湄景, 赵劲民. 脊柱畸形手术治疗现状与方向[J]. 中国矫形外科杂志, 2015, 23(03): 239-241. DOI: 10. 3977 /j. issn. 1005-8478. 2015. 03. 10.
[2] Bredow J, Boese CK, Werner CM, et al. Predictive validity of preoperative CT scans and the risk of pedicle screw loosening in spinal surgery[J]. Arch Orthop Trauma Surg, 2016, 136(8): 1063-7. DOI: 10.1007/s00402-016-2487-8.
[3]  Dubousset J. Reflections of an orthopaedic surgeon on patient care and research into the condition of scoliosis[J]. J Pediatr Orthop, 2011, 31: S1-S8.  DOI:10.1097/BPO.0b013e3181f73beb.
[4]  Ghiselli G, Wang JC, Bhatia NN, et al. Adjacent segment degeneration in the lumbar spine[J]. J Bone Joint Surg Am , 2004, 86(7): 1497-503.  DOI:10.2106/00004623-200407000-00020.
[5]  严斌, 孙永建, 欧阳汉斌, 等. 3D打印导航模块辅助腰椎椎弓根螺钉精确植入的应用研究[J]. 中国临床解剖学杂志, 2017, 35(02): 156-159.  DOI:10.13418/j.issn.1001-165x.2017.02.008.
[6]  陆晓生. 新型脊柱矫正系统的研制及相关研究[D]. 广西医科大学, 2017.
[7]  陆晓生, 黄湄景, 赵劲民. 新型脊柱畸形矫正系统的研发及应用前景[C]. //2014广西医学会骨科学分会学术年会论文集, 广西贵港, 2014.
[8] Csernátony Z, Goodship A, Szepesi K, et al. A complementary thoracic implant for the surgical correction of the scoliotic curve. A preliminary report[J]. Springer-Verlag, 2001, 11(2).  DOI:10.1007/BF01682483.
[9]  Csernátony Z, Molnár S, Hunya Z, et al. Biomechanical examination of the thoracic spine-the axial rotation moment and vertical loading capacity of the transverse process[J]. J Orthop Res, 2011, 29(12): 1904-9.  DOI:10.1002/jor.21478.
[10] Csernátony Z, Kiss L, Manó S, et al. Our experience and early results with a complementary implant for the correction of major thoracic curves[J]. Eur Spine J, 2013, 22(6): 1286-91.  DOI:10.1007/s00586-013-2698-4.
[11]赵得志, 赵建武, 曲扬, 等. 腰椎K-rod弹性内固定系统与刚性内固定系统体外应力遮挡效应的对比分析[J]. 大家健康(学术版), 2015, 9(7): 125-128.  
[12]李放. 非融合技术是治疗腰椎退变疾病的一种选择[J]. 中国脊柱脊髓杂志, 2014, 24(10): 871-872.DOI:10.3969/j.issn.1004-406X. 2014. 10. 005.
[13]张阳, 李放. 腰椎经椎弓根后路非融合技术研究进展[J]. 脊柱外科杂志, 2014, 12(1): 55-58.DOI: 10.3969/j.issn.1672-2957.2014.01.012.
[14]李伟剑, 隆振学, 梁栋柱, 等. 脊柱改良横突钩棒系统的生物力学研究[J].中国矫形外科杂志, 2019, 27(11): 1025-1029.DOI: 10.3977/j.issn. 1005-8478.2019.11.14.
[15]李兵, 姜保国, 傅中国, 等. 腰椎横突形态学研究[J]. 中国骨肿瘤骨病, 2003, 2(2): 94-97.DOI: 10.3969/j.issn.2095-252X.2003.02.008.
[16]陈世忠, 韦以宗, 林远方, 等. 腰椎横突“三长、四翘、五扁”形成年龄的影像学调查报告[J]. 颈腰痛杂志, 2020, 41(1): 107-108. DOI: 10.3969/j.issn.1005-7234.2020.01.035.
[17]Williams PL.格氏解剖学[M]. 沈阳: 辽宁教育出版社,1999. 536.
[18]吴建贤, 王斌, 石淑霞. 下腰痛生物力学特点的研究进展[J]. 中华临床医师杂志(电子版), 2014, 8(24): 4449-4453.DOI: 10.3877/cma.j.issn.1674-0785.2014.24.029.
[19]付裕, 李筱贺, 霍洪军, 等. 三维数字化手术设计在青少年特发性脊柱侧凸个性化手术中应用[J]. 中国临床解剖学杂志, 2015, 33(6): 706-711.  DOI:10.13418/j.issn.1001-165x.2015.06.019.
[20]肖进, 尹庆水, 张美超, 等. 脊柱侧凸的数字化三维重建及临床应用[J].中国临床解剖学杂志, 2008, 26(5): 494-496. DOI: 10.3969/j.issn. 1001-165X.2008.05.008.
PDF(2323 KB)

Accesses

Citation

Detail

Sections
Recommended

/