Clinical application of computer-assisted navigational template for Salter osteotomy
WU Xian-kui, LI Pei, LI Xu, SHI Qiang, LIU Liang-hong, XIE Qing-xiang
Chinese Journal of Clinical Anatomy ›› 2017, Vol. 35 ›› Issue (4) : 448-452.
Clinical application of computer-assisted navigational template for Salter osteotomy
Objective To develop and validate a navigational template for Salter osteotomy by digital technology. Methods Between April 2012 and June 2015, 21 children with unilateral developmental dislocation of the hip underwent Salter osteotomy. Preoperative CT scan pelvic images were obtained. Applying digital technology, Salter osteotomy were simulated and navigational templates for assisting in accurately cutting out a triangular bone graft from ilium were designed and manufactured. Then the navigational templates were use in the operations. The acetabular indexes(AI) of both hips were measured before and after surgery and at the latest follow-up. The efficacy wasevaluated according to Mckay clinical effects grading standard and Severin X rays grading standard. Results The AIs of both hips measured before and after surgery and at the last follow-up were analyzed with repeated measures analysis of variance. There is significant main effect in time(F=357.72, P=0.00) and in part (F=221.05, P=0.00). There is significant interaction effect between time and part(F=1984.82, P=0.00). There is significant difference between all the time levels(P=0.00).The Pearson correlation analysis indicates that the reduction of AIs of the disordered hip joints is positively related to the angels of the navigational templates(r=0.91,P=0.00) or to the apex angles of the triangular bone grafts from iliums(r=0.96,P=0.00). According to Severin X rays grading standard, 14 cases were excellent, 5 cases were good, and 2 cases were poor. The excellent and good rate was 90.48%. According to Mckay clinical effects grading standard, 13 cases were excellent, 7 cases were good, and 1 case was poor. The excellent and goodrate was 95.24%. Conclusion The computer-assisted navigational templates can assist in cutting out triangular bone grafts from ilium more rapidly and more accurately in Salter osteotomy. It can improve the success rate and accuracy of the operations, and shorten the operation time.
[1] 杨建平. 切开复位、Salter骨盆截骨、股骨近端短缩旋转截骨术治疗发育性髋关节脱位[J]. 中华骨科杂志,2010, 30(12):1252-1258.
[2] McKay DW. A comparison of the innominate and pericapsular osteotomy in the treatment of congenital dislocation of the hip[J]. Clin Orthop Relat Res, 1974, (98): 124-132.
[3] Severin E. Contribution to knowledge of congenital dislocation of hip joint:late results of closed reduction and arthrographic studies of recent cases[J].Acta Chir Scand,1941,84 (Suppl 63):S1-142.
[4] Salter RB. Role of innominate osteotomy in the treatment of congenital dislocation and subluxation of the hip in the older child[J]. J Bone Joint Surg Am,1966, 48(7):1413-1439.
[5] 熊然,张潇,李涛,等.胫骨近端后侧数字化三维形态学测量及临床意义[J].中国临床解剖学杂志,2014, 32(3):284-287.
[6] 周华,高仕长,周程鹏,等. 三维重建模拟经皮拉力螺钉固定髋臼前柱骨折的解剖学研究[J]. 中国临床解剖学杂志,2015,33(2):148-154.
[7] 王玮琦,覃涛,王婷,等. 计算机3D建模在个体化寰枢椎椎弓根钉最佳进钉方式的研究[J]. 中国临床解剖学杂志,2015, 33(3):295-300.
[8] Bungo O, Mitsuru T, Keiichi K, et al. Developing a novel custom cutting guide for curved peri-acetabular osteotomy[J].Int Orthop,2013,37(6):1033-1038.
[9] Hu Y, Yuan ZS, Kepler CK, et al. Deviation analysis of atlantoaxial pedicle screws assisted by a drill template[J]. Orthopedics, 2014, 37(5):420-427.
[10]Manuela K, Burton M, John F, et al. Image-guided distal radius osteotomy using patient-specific instrument guides[J]. J Hand Surg, 2013, 38(8):1618-1624.
[11]甘煜东,丁晶,侯春林,等. 数字化导航模板辅助全膝关节置换的临床应用[J]. 中国临床解剖学杂志,2015,33(6):700-705.
/
〈 |
|
〉 |