Finite element analyses of unilateral and bilateral pedicle screw fixation plus interbody fusion in lumbar spine

WANG Peng, WANG Jian, HU Yong, CHENG Hai-feng, JIAO Pei-feng, ZHANG Mei-chao

Chinese Journal of Clinical Anatomy ›› 2016, Vol. 34 ›› Issue (3) : 331-337.

Chinese Journal of Clinical Anatomy ›› 2016, Vol. 34 ›› Issue (3) : 331-337. DOI: 10.13418/j.issn.1001-165x.2016.03.020

Finite element analyses of unilateral and bilateral pedicle screw fixation plus interbody fusion in lumbar spine

  • WANG Peng1, WANG Jian1, HU Yong1, CHENG Hai-feng1, JIAO Pei-feng2, ZHANG Mei-chao2
Author information +
History +

Abstract

Objective To analyze biomechanical characteristics of pedicle screws and lumbar under different pressure loads between unilateral and bilateral pedicle screw fixation plus interbody fusion after discectomy by creating a normal L4~5 spinal segment finite element model. Methods A three-dimensional finite element model was created by using CT sectional images of an intact L4~5 segment of a healthy male and then model A and model B were established. Model A was unilateral pedicle screw fixation plus interbody fusion after lumbar discectomy, and model B was bilateral pedicle screw fixation plus interbody fusion after lumbar discectomy. The lumbar variation, the changes of lumbar stress and the apex stress of pedicle screw under flexion, extension, left/right lateral bending and left/right rotation were observed in the two models. Results The maximum displacement and stress of pedicle screws in model A reached max under the operating models of fixed-side flexion,and the maximum stress of lumbar reached max under extension. While in model B the maximum displacement reached max under extension,and the maximum stress of screws and lumbar reached max under rotation. There was significant difference between model A and B under fixed-side flexion and extension.  Conclusion Compared with bilateral and unilateral fixation plus fusion, the possible potential risk of instability, screw loosening and metal breakage of unilateral fixation plus fusion was greatly increased. The movement of extension, fixed-side flexion and rotation should be reduced before bone union after unilateral fixation plus fusion.

Key words

Lumbar / Bilateral pedicle screw fixation / Unilateral pedicle screw fixation / Stress / Finite element model

Cite this article

Download Citations
WANG Peng, WANG Jian, HU Yong, CHENG Hai-feng, JIAO Pei-feng, ZHANG Mei-chao. Finite element analyses of unilateral and bilateral pedicle screw fixation plus interbody fusion in lumbar spine[J]. Chinese Journal of Clinical Anatomy. 2016, 34(3): 331-337 https://doi.org/10.13418/j.issn.1001-165x.2016.03.020

References

[1] Untch C, Lin Q, Hart R, et al. Segmental motion adjacent to an instrumental lumbar fusion: the effect of extension of fusion to the sacrum[J]. Spine, 2004, 29(21):2376-2381.
[2] Kim DH, Jeong ST, Lee SS. Posterior lumbar interbody fusion using a unilateral single cage and a local morselized bone graft in the degenerative lumbar spine[J]. Clin Orthop Surg, 2009,1(4):214-221.  
[3]  Kronblum MB, Fischgrund J,Herkowitz H, et al. Degenerative lumbar spondylolisthesis with spinal stenosis:a prospective long-term study     comparing fusion with pseudoarthrosis[J]. Spine, 2004, 29(7):726-733.
[4]  Kronblum MB, Fischgrund J, Herkowitz H, et al. Degenerative lumbar spondylolisthesis with spinal stenosis: a prospective long-term study     comparing fusion with pseudoarthrosis[J]. Spine, 2004, 29(7):726-733.
[5]  Hans W, Frank H, Hendrik St. Prospective design delineation and subsequent in vitro evaluation of a new posterior dynamic stabilization system[J]. Spine, 2009, 28(3):1774-1783.
[6]  Fernandez M, Sala P, Ramfrez H, et al. A prospective randomized study of unilateral versus bilateral instrumented posterolateral lumbar fusion in degenerative spondylolisthesis[J]. Spine, 2007, 32(4):395-401.
[7]   张国桥, 何仿, 张美超, 等. 腰椎后路椎间融合内固定有限元模型的建立及内固定物力学分析[J]. 中国临床解剖学杂志, 2014, 5(5):609-612.
[8]  徐海涛, 张美超, 李义凯, 等. 坐位旋转手法对腰椎内在应力的实时监测[J]. 中国临床解剖学杂志, 2005, 23(4):420-422.
[9]  Vadapalli S, Sairyo K, Goel VK, et al. Biomechanical rationale for using polyetheretherketone(PEEK) spacers for lumbar interbody fusion: a finite element study[J].Spine, 2006, 31(26):E992-998. 
[10]Park P, Garton HJ, Gala VC, et al. Adjacent segment disease after lumbar or lumbosacral fusion:review of the literature[J].Spine, 2004, 29(17):1938-1944.
[11]董健文, 邱奕雁, 赵卫东, 等. 单侧椎弓根钉棒固定单节段腰椎及其邻近节段生物力学的研究[J]. 中国临床解剖学杂志, 2010, 28(1):85-89.
[12]Balkan C, Charles C, René St, et al. Adjacent segment mobility after rigid and semirigid instrumentation of the lumbar spine[J].Spine, 2009, 34 (17):742-749.
[13]Kong HL, Wai MY, William Yeo, et al. Clinical and radiological outcomes of open versus minimally invasive transforaminal lumbar interbody fusion[J]. European Spine Journal, 2012,22(11): 689-698.
[14]James N, Weinstein, Tor D, et al.Surgical versus nonoperative treatment for lumbar spinal stenosis four-year resuLrs of the spine patient outcomes research trial[J]. Spine, 2010, 32 (14):1627-1641.
[15]Shah RR, Mohammed S, Saifuddin A, et al. Radiologic evaluation of adjacent superior segment facet joint violation following transpedicular instrumentation of the lumbar spine[J]. Spine, 2004, 29 (18):735-742.
[16]Potter BK, Freedman BA, Verwitbe EG, et al. Transforaminal lumbar interbody fusion: clinical and radio graphic results and complications in 100 consecutive patients[J]. J Spinal Disord Tech, 2005 ,18 (11):337-346.
[17]Tuttle J, Shakir A, Choudhri HF, Paramedian approach for transforaminal lumbar interbody fusion with unilateral pedicle screw fixation. Technical note and preliminary report on 47 cages[J]. Neurosurg Focus, 2006, 20 (17):E5.

Accesses

Citation

Detail

Sections
Recommended

/