Modeling and stability comparison of length plate and lag screw fixation in the posterior column of the acetabulum
DAI Yuan-yuan, ZHANG Ying, XIA Yuan-jun, XIE Hui-bing, GUO Xiao-ze, ZHU Chang-rong
Chinese Journal of Clinical Anatomy ›› 2016, Vol. 34 ›› Issue (2) : 214-219.
Modeling and stability comparison of length plate and lag screw fixation in the posterior column of the acetabulum
Objective To evaluate the biomechanical stability of long plates and retrograde percutaneous lag screws in internal fixation surgery for the treatment of acetabular posterior column fracture.Methods Finite element modeling software was used to establish internal fixation models for treating an acetabular posterior column fracture, including a retrograde percutaneous lag screw (A) and a long plate (B). The finite element analysis was carried out in standing and sitting by the same loading way. Results In standing and sitting postures , the maximum stress (A were 12.35 MPa, 3.30 MPa; B was 9.75 MPa, 2.87 MPa; respectively), the maximum displacement(0.45 mm and 0.38 mm respectively for A; 0.44 mm and 0.32 mm respectively for B) and the mean node displacement of fracture lines (0.404±0.049 mm and 0.341±0.020 mm for A; 0.381 ± 0.055 mm and 0.300 ± 0.019 mm respectively for B) of posterior column acetabular fracture were all larger in A than in B, and the difference between A and B were significant. Conclusion Compared with retrograde percutaneous lag screws, internal fixation using long plates for the treatment of posterior column acetabular fracture was better for mechanical stability.
Acetabulum / Posterior column fracture / Finite elementanalysis / Biomechanics
[1] 吴淑琴,潘宏侠,裴葆青. 髋臼横断骨折后柱长/短钢板内固定的有限元建模及分析[J]. 北京生物医学工程, 2011,30(1):1-4.
[2] 王庆贤,张英泽,潘进社,等. 逆行髋臼后柱拉力螺钉内固定的应用解剖学[J]. 中国临床解剖学杂志,2006,24(1):36-38.
[3] Puchwein P, Enninghorst N, Sisak K, et al. Percutaneous fixation of acetabular fractures: computer-assisted determination of safe zones, angles and lengths for screw insertion[J]. Arch Orthop Trauma Surg, 2012,132(6):805-811.
[4] 张潇,杨晓东,夏广,等. 经皮逆行拉力螺钉固定髋臼后柱骨折的有限元对比研究[J]. 创伤外科杂志,2015,17(4): 311-314.
[5] Phillips AT, Pankaj P, Howie CR, et al. Finite element modelling of the pelvis: inclusion of muscular and ligamentous boundary conditions[J]. Med Eng Phys, 2007,29(7): 739-748.
[6] 高应超,郭征,付军,等.坐位骨盆的三维有限元分析[J].中国组织工程研究与临床康复, 2011, 22: 3997-4001.
[7] 汪方,陈博,王秋根,等. 髂骨翼与髋臼上置钉技术在Tile B1型骨盆骨折外固定的有限元研究[J]. 中华创伤骨科杂志,2011,13(6):534-538.
[8] Yildirim AO, Alemdaroglu KB, Yukse HY, et al. Finite element analysis of the stability of transverse acetabular fractures in standing and sitting positions by different fixation options[J]. Injury,2015,46(suppl 2): S29-S35.
[9] 黄进成,刘曦明,蔡贤华,等. 前路钛板加方形区螺钉联合后柱螺钉治疗髋臼双柱骨折的有限元分析[J]. 中国矫形外科杂志,2014,22(12):1104-1110.
[10] 张丕军,洪顾麒,陈凯宁,等. 髋臼后柱骨折逆行拉力螺钉固定导向装置研制及初步验证[J]. 中华创伤杂志,2014,30(3):204-210.
[11] Ji T,Guo W,Tang XD, et a1.Reconstruction of type II+III pelvic resection with amodular hemipelvic endoprosthesis:a finite element analysis study[J].Oahop Surg,2010,2(4):272-277.
[12]吴啸波,张奇,郭明珂,等. 髋臼后柱骨折不同方式钢板内固定的稳定性研究[J]. 第三军医大学学报, 2010,32(7):665-668.
[13]吴啸波,张奇,郭明珂,等. 髋臼后柱骨折模型建立及髋臼后柱骨折钢板内固定和拉力螺钉内固定稳定性比较[J]. 中国组织工程研究与临床康复, 2009, 13(52):10236-10240.
[14]范永盛,尹维刚,史增元,等. 三维重建模型模拟拉力螺钉固定髋臼后柱骨折的研究[J]. 中国临床解剖学杂志,2013,31(3):241-245.
/
〈 |
|
〉 |