Verification of the limitations about two-dimensional image navigation for femoral neck fracture’s reduction by three-dimensional measurement

Chinese Journal of Clinical Anatomy ›› 2015, Vol. 33 ›› Issue (5) : 535-540.

Chinese Journal of Clinical Anatomy ›› 2015, Vol. 33 ›› Issue (5) : 535-540. DOI: 10.13418/j.issn.1001-165x.2015.05.011

Verification of the limitations about two-dimensional image navigation for femoral neck fracture’s reduction by three-dimensional measurement

  • WANG Song 1,2, ZHANG Tao1,  ZHANG Peng-yu2, MA Xin-long2, LV Guang-shui 1,2, HAN Zhe2
Author information +
History +

Abstract

Objective  A three-dimensional measuring method was proposed for evaluation of the reduction quality of displaced or undisplaced femoral neck fractures with closed reduction and internal fixation surgery. Then, summarizing up the displacement tendency of the femoral head provides a theoretical basis for better fracture treatment using an appropriate manual reduction. Methods 91 patients with femoral neck fractures were categorized into two groups: an undisplaced fracture group and a displaced fracture group. Three-dimensional models were constructed.  Some parameters were measured: spatial distance displacement of the femoral head center(d), deflection angle of the femoral head (α); Self-rotation angle of the femoral head (β), shortened values of the femoral neck(L). Results There was no significant difference between the undisplaced and displaced groups concerning the displacement distance of femoral head’s center, flection angle (P=0.62; P=0.70). There was significant difference between the undisplaced and displaced groups concerning the self-rotation angle of the femoral head, shortened values of the femoral neck (P=0.047; P=0.019). Conclusion It is not adequate to evaluate the reduction quality of femoral neck fractures merely using the two-dimensional method. X-ray radiographs have some limitations in accurate descriptions when it comes to spatial displacement, especially rotation displacement of femoral head, while the three-dimensional method, such as spiral CT seems a better choice.

Key words

 Femoral neck fracture / Reduction / Three-dimensional measurement

Cite this article

Download Citations
Verification of the limitations about two-dimensional image navigation for femoral neck fracture’s reduction by three-dimensional measurement[J]. Chinese Journal of Clinical Anatomy. 2015, 33(5): 535-540 https://doi.org/10.13418/j.issn.1001-165x.2015.05.011

References

[1] Kelly DW, Kelly BD. A novel diagnostic sign of hip fracture mechanism in ground level falls: two case reports and review of the literature[J]. J Med Case Rep, 2012,6:136.
[2] Bhandari M, Chiavaras M, Ayeni O, et al. Assessment of radiographic fracture healing in patients with operatively treated  femoral neck fractures[J]. J Orthop Trauma, 2013,27(9):e213-e219.
[3] Weil Y A, Safran O, Greenberg A, et al. Outcome of proximal femoral fractures caused by cycling in the young and mid-aged[J]. Injury, 2014, 45(8):1251-1255.
[4] Mendez A A, Eyster R L. Displaced nonunion stress fracture of the femoral neck treated with internal fixation and bone graft. A case report and review of the literature[J]. Am J Sports Med, 1992, 20(2):230-233.
[5]  Kambic R E, Roberts T J, Gatesy S M. Long-axis rotation: a missing degree of freedom in avian bipedal locomotion[J]. J Exp Biol, 2014, 217(Pt 15):2770-2782.
[6]  马信龙, 付鑫, 马剑雄, 等. 股骨头内松质骨空间分布和力学性能变化有限元分析[J]. 医用生物力学, 2010, 25(6):465-470.
[7]  Bergmann G, Deuretzbacher G, Heller M, et al. Hip contact forces and gait patterns from routine activities[J]. J Biomech, 2001, 34(7):859-871.
[8]  何国忠, 庞清江, 陈先军, 等. 股骨头钻孔减压孔径对股骨颈生物力学影响的实验研究[J]. 中国临床解剖学杂志, 2013, 31(1):100-103.
[9]  Palm H, Gosvig K, Krasheninnikoff M, et al. A new measurement for posterior tilt predicts reoperation in undisplaced femoral  neck fractures: 113 consecutive patients treated by internal fixation and followed for 1 year[J]. Acta Orthop, 2009, 80(3):303-307.
[10] Zlowodzki M, Brink O, Switzer J, et al. The effect of shortening and varus collapse of the femoral neck on function after fixation of intracapsular fracture of the hip: a multi-centre cohort study[J]. J Bone Joint Surg Br, 2008, 90(11):1487-1494.

Accesses

Citation

Detail

Sections
Recommended

/