The establishment and significance of standard parts library of proximal tibia plates based on thin-section CT image

Chinese Journal of Clinical Anatomy ›› 2015, Vol. 33 ›› Issue (3) : 291-294.

Chinese Journal of Clinical Anatomy ›› 2015, Vol. 33 ›› Issue (3) : 291-294. DOI: 10.13418/j.issn.1001-165x.2015.03.013

The establishment and significance of standard parts library of proximal tibia plates based on thin-section CT image

  • YANG Yang1,   ZHANG Guo-dong1,   CHEN Xuan-huang2,   ZHENG Xiao-hui3,   HUANG Hua-jun1,   WU Zhang-lin1,   OUYANG Han-bin1,   LU Jian-jun4,   HUANG Wen-hua1
Author information +
History +

Abstract

 Objective   To discuss the method of establishing standard parts library of proximal tibia plates and its clinical significance.    Methods    The original image of six sets of full-size proximal tibia plates date were collected which is scanned by thin-section CT, and processed with Mimics 14.0 for the three-dimensional reconstruction, then the models were exported to Geomagic by STL format for morphological optimizing.  The optimized models were exported to Mimics for volume rendering. Cylinder-shaped screw channels was drawn by MedCAD for simulation of channel direction of real-locking screws, and the establishment of standard parts library of plates with screws was then completed.   Results   (1) The establishment of 186 standard parts library of plates with screws was completed. (2) By morphological optimizing in Geomagic and volume rendering in Mimics, the 3D model of plate has high simulation degree. Conclusions   (1) Based on CT scan data ,the standard parts library of orthopedic plate can be achieved by reverse engineering software.  (2) The selective combinations between plate and screw channels were suitable for digital design of fracture internal fixation operation.

Key words

tibial plateau fracture / Plate / Standard parts library / Reverse engineering / Virtual surgery

Cite this article

Download Citations
The establishment and significance of standard parts library of proximal tibia plates based on thin-section CT image[J]. Chinese Journal of Clinical Anatomy. 2015, 33(3): 291-294 https://doi.org/10.13418/j.issn.1001-165x.2015.03.013

References

[1] Onderko LL, Rehman S. Treatment of articular fractures with continuous passive motion[J]. Orthop Clin N Am, 2013,44(3):345-356.
[2]  张国栋, 陶圣祥, 郑和平, 等. 基于三维重建技术的股骨远端数字钢板设计[J].实用骨科杂志, 2010, 16(1):35-38.
[3]  刘长荣, 陈修龙, 闫栋梁, 等. 基于逆向造型的三维参数化标准件库的开发[J].机械科学与技术, 2006, 25(4):458-460.
[4] Sousa MVS, Vasconcelos EC, Janson G, et al. Accuracy and reproducibility of 3-dimensional digital model measurements[J]. Am J Orthod Dentofac, 2012, 142(2):269-273.
[5]  Dirksen D, Diederichs S, Runte C, et al. Three-dimensional acquisition and visualization of dental arch features from optically digitized models[J]. J Orofac Orthop,1999, 60(2):152-159.
[6]  Ramakrishnan B, Sriraam N. Internet transmission of DICOM images with effective low bandwidth utilization[J]. Digit Signal Process, 2006,16(6):825-831.
[7]  Link TM, Berning W, Scherf S, et al. CT of metal implants: Reduction of artifacts using an extended CT scale technique[J]. J Comput Assist Tomo, 2000, 24(1):165-172.
[8]  Yazdia M, Gingras L, Beaulieu L. An adaptive approach to metal artifact reduction in helical computed tomography for radiation therapy treatment planning: Experimental and clinical studies[J]. Int J Radiat Oncol Biol Phys, 2005, 62(4):1224-1231.
[9]  Buckwalter K,傅强. 矫形金属植入物CT, MR的最佳影像技术方案[J].放射学实践, 2007,22(7):23.
[10] 周泽俊,胡永胜,高斌.多层螺旋CT图像伪影的分析[J].中国CT和MRI杂志, 2008, 6(5):72-73.