Three-dimensional finite element model of posterior fusion surgery for L4~S1 and analysis of stress distributions
LI Su-Huan, LIU Bin, ZHANG Guo-Qiao, HE Fang, ZHANG Mei-Chao, JIAO Pei-Feng
Chinese Journal of Clinical Anatomy ›› 2014, Vol. 32 ›› Issue (5) : 609-612.
Three-dimensional finite element model of posterior fusion surgery for L4~S1 and analysis of stress distributions
Objective To develop a three-dimensional finite element model for posterior fusion surgery of L4~S1 and evaluate the stress distributions of the pedicle screw and cage. Method The finite element model of normal lumbosacral vertebral L4~S1 segments with removal of L5~S1 intervertebral disc was established through CT scan,three-dimensional reconstruction by using Mimics,surface treatment by using Freeform and analysis by using Ansys, respectively. The model was fixed by the posterior pedicle screws and intervertebral fusion. The model was analyzed under different conditions such as flexion,extension,bending and rotation under the same load. Results All the stress mostly concentrated on the screw tail and junction between the arch bar and the screw. The stress on the Cage was mainly located in the anterior part except under the condition of rotation, which is located at the middle. The peak stress on screw and cage are 2.96×107 N/m2 , 5.65×106 N/m2 in flexion, 2.98×107 N/m2 , 6.08×106 N/m2 in extension, 3.06×107 N/m2 ,9.71×106 N/m2 in bending, 2.96×107 N/m2, 1.00×106 N/m2 in rotation. Conclusion Three-dimensional finite element model of posterior fusion surgery of L4~S1 has been developed successfully and the stress distribution of pedicle screw and cage are close to clinical record, which can provide a significant guidance for clinical practice.
Finite element / Intervertebral fusion / Three-dimensional reconstruction / Pedicle screw
[1] Jutte PC,Castelein RM. Complications of pedicle screws in lumbar and lumbosacral fusions in l05 consecutive primary operations
[J].Eur Spine J, 2002, 11(6): 594-598.
[2] Fagan MJ,Ju1ian S,Mohsen AM.Finite element analysis in spine research
[J].J Engneering Med, 2002, 216(5):281-298.
[3] Pitzen T,Geisler FH,Matthis D,et a1.Motion of threaded cages in posterior lumbar interbody fusion
[J].Eur Spine J, 2000, 9(6):571-576.
[4] Zhong ZC,Wei SH,Wang JP,et al.Finite element anaylsis of the lumbar spine with a new cage using a topology optimization method
[J].Med Eng Phys, 2006, 28(1):90-98.
[5] Wilcox RK.The influence of material property and morphological parameters on specimen-specific finite element models of porcine vertebral bodies
[J].J Biomech,2007,40(3):669-673.
[6] 陈志明,马华松,赵杰,等.腰椎单侧椎弓根螺钉固定的三维有限元分析
[J].中国脊柱脊髓杂志,2010,20(8):684-688.
[7] Kim Y. Finite element analysis of anterior lumbar interbody fusion :threaded cylindrical Cage and pedicles crew fixation
[J].Spine,2007,32 (23):2558-2568.
[8] 陆声,徐永清,张美超.腰椎前路椎间融合后不同固定方式的生物力学特性
[J].脊柱外科杂志, 2008,6(1):28-31.
[9] 宋富立,靳安民,王瑞,等.短节段椎弓根内固定系统术后断裂临床分析
[J].中国骨与关节损伤杂志,2005,20(6):376-378.
[10] Katonis P,Christoforakis J,Kontakis G, et a1.Complications and problems related to pedicle screw fixation of the spine
[J].Clin Orthop Re1at Res, 2003, (411):86-94.
[11]于博, 靳安民, 方国芳.腰椎弹性内固定与刚性内固定的应力对比研究
[J].中国临床解剖学杂志,2009,27(4):469-473.
/
〈 |
|
〉 |