Applied anatomic studies of cervical anterior transpedicular screw fixation

LI Rui-Feng, TUN Yi-Min

Chinese Journal of Clinical Anatomy ›› 2014, Vol. 32 ›› Issue (5) : 529-532.

Chinese Journal of Clinical Anatomy ›› 2014, Vol. 32 ›› Issue (5) : 529-532. DOI: 10.13418/j.issn.1001-165x.2014.05.006

Applied anatomic studies of cervical anterior transpedicular screw fixation

  • LI Rui-feng,WU Yi-ming
Author information +
History +

Abstract

Objective To provide relevant anatomic parameters for the promotion of the Cervical anterior transpedicular screw fixation(ATPS).  Methods 30 sets adult normal cervical specimens were randomly selected, and the scanned data were imported to the MIMICS 13.0 software;the related anatomical parameters and the pedicle screw parameters of ATPS were measured. Then the obtained data were subject to statistical anylysis. Rusults Through measurement the pedicle screw parameters, the best enterance point for screws and the best enterance channel for the screw could be determined. It could be found from the measurement that the height of the cervical vertebral pedicle was larger than the width and the the largest screw it can contain was 4.5 mm in diameter 30 mm in length. Conclusion ATPS can be applied to the treatment of cervical vertebra disease as a new fixation technology. It may provide a better help for the treatment of some cervical vertebral disease, such as tumor, serious osteoporosis and three-column injury of the cervical spine.

Key words

 Cervical vertebrae / Anterior / Anatomy / Pedicle / Screw fixation

Cite this article

Download Citations
LI Rui-Feng, TUN Yi-Min. Applied anatomic studies of cervical anterior transpedicular screw fixation[J]. Chinese Journal of Clinical Anatomy. 2014, 32(5): 529-532 https://doi.org/10.13418/j.issn.1001-165x.2014.05.006

References


[1]  Abel R, Ruf S, Spahn B. Cervical spinal cord injury and degluti-tion disorders[J].Dysphagia, 2004, 19(2):87-94.

[2]  Barsa P, Suchomel P. Factors affecting sagittal malalignment due to cage subsidence in standalone cage assisted anterior cervical fusion
[J].Eur Spine J, 2007,16(9):1395-1400.

[3] Kouyoumdjian P, Gille O, Aurouer N, et al. Cervical vertebral osteoradionecrosis:surgical management,complications and flap coverage- a case report and brief review of the literature[J].Euro Spine J, 2009,18( Suppl 2):S258-S264.

[4] Koller H,Hempfing A,Ferraris L, et al. 4-and 5-level anterior fusions of the cervical spine: review of literature and clinical results
[J]. Eur Spine J, 2007,16(12):2055-2071.

[5]  Ning X,Wen Y, Xiao-Jian Y, et al. Anterior cervical locking plate-related complications; prevention and treatment recommendations
[J].Int Orthop, 2008,32(5):649-655.

[6] Koller H, Hempfing A, Acosta F,et al. Cervical anterior transpedicular screw fixation. Part I: Study on morphological feasibility, indications, and technical prerequisites
[J].Eur Spine J, 2008,17(4):523-538.

[7]  李严兵,张韶辉,谢叻, 等. 颈椎椎弓根进钉通道、进钉点与椎体外侧面三维关系定位分析
[J].中国骨科临床与基础研究杂志, 2010, 32(2):29-34.

[8] Abumi K, Kaneda K, Shono Y,et al. One-stage posterior decompression and reconstruction of the cervical spine by using pedicle screw fixation systems.
[J].J Neurosurg, 1999, 90(1 suppl):19-26.

[9] Maat GJ, Matricali B, van Persijn van Meerten EL, Postnatal development and structure of the neurocentral junction. Its relevance for spinal surgery
[J].Spine,1996, 21(6):661-666.

[10] Abumi K, Itoh H, Taneichi H, et al. Transpedicular screw fixation for traumatic lesions of the middle and lower cervical spine:description of the techniques and preliminary report
[J]. Spinal Disord ,1994,7(1):19-28.

[11] Jeanneret B, Gebhard JS, Magerl F. Transpedicular screw fixation of articular mass fracture-separation: results of an anatomical study and operative technique
[J]. Spinal Disord ,1994, 7(3):222-229.

[12] Jones EL, Heller JG, Silcox DH, et al. Cervical pedicle screws versus lateral mass screws. Anatomic.feasibility and biomechanical comparison
[J]. Spine, 1997, 22(9):977-982.

[13] 王东来,唐天驹,黄士中,等.下颈推稚弓根内固定的解剖学研究与临床应用
[J].中华骨科杂志,1998,18(4):659-662.

[14] Panjabi MM,Shin EK,Chen NC,et al. Internal morphology of human cervical pedicles
[J]. Spine, 2000, 25(10):1197-1205.

[15] Kosmopoulos V, Schizas C. Pedicle screw placement accuracy: a meta-analysis
[J]. Spine, 2007, 32(3):111-118.

[16] Isu T,Minoshima S,Takeda M,et al.A surgical technique for a vertebral column autograft using the intervertebral disc for cervicaldisc disease
[J].Acta Neurochir(Wien),1998,140(3):267-273.

[17] Kantelhardt SR, Oberle J, Derakhshani S, et al. The cervical spine and its relation to anterior plate-screw fixation: a quantitative study
[J].Neurosurg Rev, 2005, 28(4):308-312.

[18]Kotani Y, Cunningham BW, Abumi K, et al. Biomechanical analysis of cervical stabilization systems. An assessment of transpedicular screw fixation in the cervical spine
[J].Spine ,1994,19(22):2529-2539.

[19] 王东来,唐天驷,黄世忠,等. 五种颈椎内固定方法的稳定性生物力学评价
[J].中华外科杂志, 1999, 37(5): 301-303.

[20] Ludwig SC, Kramer DL, Balderston RA, et al. Placement of pedicle screws in the human cadaveric cervical spine: comparative accuracy of three techniques
[J]. Spine, 2000, 25(13):1655-1667.

[21] Kosmopoulos V, Schizas C. Pedicle screw placement accuracy: ameta-analysis
[J].Spine, 2007, 32(3):111-120.

Accesses

Citation

Detail

Sections
Recommended

/